Skip to content
Spezialcompounds Reference guide to engineering plastic compounds Deutsch

Halogen-free flame retardant plastics

Halogen-free flame retardant plastics reach their flammability rating without additives containing bromine or chlorine, usually with phosphorus-based, nitrogen-based or mineral flame retardants. Fire behaviour is demonstrated with UL 94 (classes HB, V-2, V-1, V-0, 5VB, 5VA) and with the glow-wire values GWFI and GWIT to IEC 60695-2-12 and -2-13. Every class applies only to the tested wall thickness.

Last reviewed:

At a glance

  • UL 94 is in its seventh edition of 2023, last revised in July 2026.
  • V-0, V-1 and V-2 come from the vertical test, 5VA and 5VB from the 500 W test.
  • A Yellow Card shows a material's tested values for each minimum thickness and colour.
  • GWFI and GWIT are values from the glow-wire test on the material.
  • For printed circuit boards, halogen-free means below 900 ppm each of chlorine and bromine and below 1,500 ppm combined.

UL 94: flammability classes and test principle

What does UL 94 test?

UL 94 tests on standard bars and plaques how a plastic reacts to a small open flame. The standard applies to plastics in parts of devices and appliances and is in its seventh edition of 28 February 2023, last revised on 2 July 2026.⁠[1] It has twelve flammability classes in total.⁠[5] For HB the burning rate counts; for the V classes afterflame time, afterglow and flaming drips.⁠[2]

Six flammability classes under UL 94 from HB to 5VAHB: horizontal, burning rate; V-2: 30 s, cotton may ignite; V-1: 30 s, cotton must not ignite; V-0: 10 s, cotton must not ignite; 5VB: 500 W flame, hole permitted; 5VA: 500 W flame, no hole.HBhorizontal, burning rateV-230 s, cotton may igniteV-130 s, cotton must not igniteV-010 s, cotton must not ignite5VB500 W flame, hole permitted5VA500 W flame, no hole
Six classes under UL 94, ordered by the strictness of the publicly stated criteria. HB, V and 5V are separate tests. Source: [2].
Fire classes under UL 94 and their international equivalent
ClassTest arrangementCriteria according to public informationIEC equivalent (method)
HBhorizontal, once for 30 sat most 40 mm/min at 3 to 13 mm thickness, 75 mm/min belowIEC 60695-11-10:2013 (A)
V-2vertical, twice for 10 safterflame at most 30 s; drips may ignite the cottonIEC 60695-11-10:2013 (B)
V-1as V-2times as V-2; cotton must not igniteIEC 60695-11-10:2013 (B)
V-0as V-2afterflame at most 10 s; cotton must not igniteIEC 60695-11-10:2013 (B)
5VB500 W flame, five timesafterflame at most 60 s; burn-through permittedIEC 60695-11-20:2015
5VAas 5VBtimes as 5VB; no burn-throughIEC 60695-11-20:2015
Sources: criteria and equivalent after [2]; editions after [1], [3], [4].

What role does wall thickness play?

A UL 94 class only applies together with the wall thickness at which it was tested. The Yellow Card therefore states a minimum thickness and the colour for each class.⁠[5] The standard does not apply to parts thicker than 13 mm.⁠[1]

Which IEC standards correspond to UL 94?

Internationally, IEC 60695-11-10 corresponds to classes HB and V, and IEC 60695-11-20 to classes 5VA and 5VB.⁠[2] IEC 60695-11-10 describes the test with the 50 W flame and applies in its second edition of May 2013.⁠[3] IEC 60695-11-20 applies in its second edition of April 2015 and only to materials that already reach V-0 or V-1.⁠[4]

The texts of the standards are subject to a charge and were not available to the editors. The information comes from public abstracts of the publishers and of a test institute.

Yellow Card: what the card shows

What is a Yellow Card?

A Yellow Card is the digital data sheet of a plastic whose values an independent test body has tested to the relevant standards. It is created once a material is listed as a Recognized Component. The material is then monitored regularly.⁠[5]

Which values are on the card?

For each minimum thickness and colour, the card states the UL 94 flammability class and further values:⁠[5]

  • RTI (Relative Thermal Index): highest service temperature at which critical properties are retained over the service life.
  • HWI (Hot Wire Ignition): resistance to ignition by a heated wire.
  • HAI (High Arc Ignition): behaviour under electric arcs on or just above the surface.
  • CTI (Comparative Tracking Index): tendency to form tracking paths, tested to IEC 60112.

Many values appear as a performance level category (PLC) from 0 to 5, where 0 is the best. The card can also contain glow-wire values and the note “non-halogenated”.⁠[5] Short-term values are governed by UL 746A, long-term values by UL 746B.

Glow wire: GWFI, GWIT and household appliances

What do GWFI and GWIT mean?

GWFI and GWIT are values from the glow-wire test on the material. The GWFI (Glow-Wire Flammability Index) is the highest temperature at which the specimen does not ignite or extinguishes within 30 seconds of removing the glow wire.⁠[6] The GWIT (Glow-Wire Ignition Temperature) is 25 K or 30 K above the highest test temperature at which the material does not ignite or no flame burns longer than 5 seconds.⁠[7] Both standards are in their third edition of 2021.⁠[6]⁠[7] The test apparatus is described in IEC 60695-2-10, in its fourth edition since May 2026.

What does IEC 60335-1 require for household appliances?

IEC 60335-1 is the safety standard for household appliances and sets glow-wire requirements for plastic parts near electrical connections. It applies in its sixth edition of 2020, consolidated with Amendment 1 since October 2025.⁠[8] A patent publication of 2014 summarises the requirement for appliances operated unattended as follows: it concerns plastic parts that support connections carrying more than 0.2 A or lie within 3 mm of them. The material needs a GWFI of 850 °C and a GWIT of 775 °C, or the finished part passes the test at 750 °C.⁠[9] Whether the current edition contains these figures unchanged must be checked against the text of the standard.

A good UL 94 class does not predict the glow-wire values. According to the same patent publication, many halogen-free materials with a good V class do not meet the GWIT requirement, or only just.⁠[9]

Halogen-free: definition, flame retardants and limits

What does halogen-free mean?

Halogen-free means that a material contains practically no chlorine and no bromine. The editors found no general definition for thermoplastics. One reference used is IEC 61249-2-21, a printed circuit board standard of 2003. Under it, chlorine and bromine are each below 900 ppm and below 1,500 ppm combined.⁠[10]

Which flame retardants come into question?

Halogen-free systems use phosphorus compounds, nitrogen compounds or metal hydroxides, often in combination.⁠[11] Halogenated flame retardants release toxic and corrosive gases in a fire.⁠[11] Their partner antimony trioxide does not act as a flame retardant on its own but, as a synergist, enhances the effect of the halogens. According to a dossier of March 2020, it is classified in the EU under harmonised classification as carcinogenic category 2 (H351).⁠[12]

Groups of flame retardants compared
GroupExamplesMode of actionNote
Phosphorus-basedAluminium phosphinates, hypophosphites, DOPO derivativesradicals inhibit the flame; char layer as barrieroften combined with nitrogen
Nitrogen-basedMelamine cyanurate, melamine polyphosphateinert gases dilute the fire gases; protective layeralso combined with phosphorus
MineralAluminium hydroxide, magnesium hydroxidedecomposition absorbs heat; water vapour dilutes; oxide layer protectslarge amounts needed
Halogenatedbrominated additives with antimony trioxidegas phasetoxic and corrosive fire gases
Sources: [11], [12]. Examples from the research literature, not a market overview.

Where are halogen-free grades used?

The sources evaluated name applications close to electrical connections:

  • Electrical engineering: connectors, switches and housings, for which the dossier names systems with antimony trioxide.⁠[12]
  • Household appliances: parts at connections of appliances operated unattended.⁠[9]
  • Electronics: base material for printed circuit boards.⁠[10]

Where are the limits?

A review article names cost and the required concentration as the two hurdles.⁠[11]

  • Mechanics: a blend of PA6 and PP reached V-1 with 30 % by weight of magnesium hydroxide; impact strength suffered.⁠[11]
  • Loading: in glass-fibre-reinforced PA6, 20 % by weight of a hypophosphite was considered the mechanical upper limit.⁠[11]
  • Transferability: flammability class, glow-wire values and CTI are separate tests.⁠[5]⁠[9]

What the material supplier needs to know

This information belongs in an enquiry:

  • UL 94 class and thinnest wall thickness of the part
  • Glow-wire requirement with temperature: GWFI, GWIT or test on the finished part
  • Product standard of the end device, for example IEC 60335-1
  • Definition of halogen-free with limit value and reference document
  • Required Yellow Card entries: RTI, HWI, HAI, CTI
  • Colour of the part
  • Mechanical requirements
  • Continuous temperature and processing method

Frequently asked questions

What does UL 94 V-0 mean?

V-0 is the strictest class of the vertical test under UL 94. After each flame application the bar may continue to flame for at most 10 seconds and must not ignite the cotton below.

What is the difference between 5VA and 5VB?

Both come from the 500 W test under UL 94. With 5VA no hole may form, with 5VB it may.

Why is a wall thickness stated after the flammability class?

A UL 94 class only applies to the tested thickness. The Yellow Card therefore states a minimum thickness for each class.

What is a Yellow Card?

The Yellow Card is the digital data sheet of a plastic with independently tested values. Among other things it states flammability class, RTI, HWI, HAI and CTI.

What does RTI mean?

The Relative Thermal Index is the highest service temperature at which critical properties are retained over the service life.

What is the difference between GWFI and GWIT?

The GWFI is the highest glow-wire temperature at which the specimen does not ignite or extinguishes within 30 seconds. The GWIT is 25 K or 30 K above the highest temperature at which no flame burns longer than 5 seconds.

When is a plastic considered halogen-free?

One reference is the printed circuit board standard IEC 61249-2-21: chlorine and bromine each below 900 ppm, combined below 1,500 ppm.

Which flame retardants are halogen-free?

Halogen-free are phosphorus-based agents such as aluminium phosphinates, nitrogen-based ones such as melamine cyanurate and mineral ones such as magnesium hydroxide.

Is antimony trioxide a flame retardant?

Not on its own. As a synergist, antimony trioxide enhances the effect of halogenated flame retardants.

Sources

All sources retrieved and checked on 23 November 2026.

  1. UL 94, Tests for Flammability of Plastic Materials for Parts in Devices and Appliances. 7th edition of 28 February 2023, last revised on 2 July 2026. Catalogue entry with scope. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL94_7_S_20230228
  2. UL Solutions: Combustion (fire) tests for plastics. Public description of the tests and classes under UL 94 with IEC equivalent. https://www.ul.com/services/combustion-fire-tests-plastics
  3. IEC 60695-11-10:2013, Fire hazard testing – Part 11-10: Test flames – 50 W horizontal and vertical flame test methods. 2nd edition, May 2013. Abstract. https://webstore.iec.ch/en/publication/2938
  4. IEC 60695-11-20:2015, Fire hazard testing – Part 11-20: Test flames – 500 W flame test method. 2nd edition, April 2015. Abstract. https://webstore.iec.ch/en/publication/22282
  5. UL: Yellow Card, brochure on the recognition programme for plastics with explanation of the values. https://code-authorities.ul.com/wp-content/uploads/sites/2/2017/01/Yellow-Card-Brochure.pdf
  6. IEC 60695-2-12:2021, Fire hazard testing – Part 2-12: Glow-wire flammability index (GWFI) test method for materials. 3rd edition, October 2021. Abstract. https://webstore.iec.ch/en/publication/62845
  7. IEC 60695-2-13:2021, Fire hazard testing – Part 2-13: Glow-wire ignition temperature (GWIT) test method for materials. 3rd edition, August 2021. Abstract. https://webstore.iec.ch/en/publication/62846
  8. IEC 60335-1:2020+AMD1:2025 CSV, Household and similar electrical appliances – Safety – Part 1: General requirements. Edition 6.1, October 2025. Abstract. https://webstore.iec.ch/en/publication/110266
  9. US Patent Application 2014/0371357 A1: Live part in unattended household appliances. Background section. https://patents.google.com/patent/US20140371357A1/en
  10. US Patent 11,015,052: Halogen-free low dielectric resin composition. Definition of halogen-free with reference to IEC 61249-2-21. https://image-ppubs.uspto.gov/dirsearch-public/print/downloadPdf/11015052
  11. Levinţa, N.; Vuluga, Z.; Teodorescu, M.; Corobea, M. C.: Halogen-free flame retardants for application in thermoplastics based on condensation polymers. SN Applied Sciences 1 (2019), 422. https://doi.org/10.1007/s42452-019-0431-6
  12. Öko-Institut: RoHS Annex II Dossier for Diantimony trioxide (flame retardant). Version 3, 30 March 2020. https://rohs.exemptions.oeko.info/fileadmin/user_upload/RoHS_Pack_15/Final_Results/Diantimony_trioxide_RoHS_Dossier_V3_final.pdf

Related topics

  • Rail: EN 45545
    Fire protection for railway vehicles: hazard levels, requirement sets and tests for plastics.
  • High-temperature polyamides
    PPA, PA9T and PA6/6T: heat resistance, water absorption and soldering.
  • PPS and PEEK
    Chemical resistance, fire behaviour and continuous use temperature.
  • Thermally conductive plastics
    The value in W/(m·K), test methods, electrically insulating or conductive, applications and limits.

This page is technical information, not advice on standards, law or design. The standards cited in their current edition and the material manufacturers' test reports are authoritative.