EN 45545-2 specifies the fire behaviour that materials and components in railway vehicles must demonstrate. The current edition is EN 45545-2:2020+A1:2023. What counts is the hazard level of the vehicle (HL1 to HL3) and the requirement set of the component, for many electrotechnical plastic parts R22 (interior) or R23 (exterior). These sets test oxygen index, smoke density and smoke toxicity.

Last reviewed:

At a glance

  • The hazard level HL1 to HL3 follows from the operation category and design category of the vehicle.
  • A component must pass every test in its requirement set.
  • R22 applies to interior components, R23 to exterior components.
  • The current edition is EN 45545-2:2020+A1:2023, published in Germany as DIN EN 45545-2:2023-12.
  • A test result applies to the tested thickness and specimen form, not to a material in general.

Hazard levels: how a vehicle is classified

How is the EN 45545 series structured?

EN 45545 governs fire protection in railway vehicles in several parts. Part 1 defines operation categories and design categories, Part 2 the requirements for the fire behaviour of materials and components, Part 3 the fire resistance of fire barriers.⁠[1]⁠[3]

What are operation categories and design categories?

The operation category describes the line, the design category the vehicle. The four operation categories (OC 1 to OC 4) depend on the infrastructure, above all on underground sections.⁠[3] A guide from an electrical industry association summarises in simplified form: OC 1 for operation above ground, OC 2 and OC 3 for tunnels of different length, OC 4 for lines without side evacuation.⁠[4] Among the design categories, A denotes vehicles of automatic trains without trained staff on board, D double-deck vehicles, S sleeping and couchette cars, N all other vehicles.⁠[3]

How does this lead to HL1, HL2 or HL3?

The hazard level (HL) is read from Table 1 of EN 45545-2 using operation category and design category.⁠[3] According to the guide mentioned: in OC 1, design categories N, A and D receive HL1, sleeping cars HL2. In OC 2, HL2 applies to all design categories. In OC 3, HL2 applies, HL3 for sleeping cars. In OC 4, HL3 applies to all design categories.⁠[4]

The European TSI for locomotives and passenger rolling stock prescribes the operation category: OC 2 for passenger vehicles of fire safety category A and for freight locomotives, OC 3 for passenger vehicles of category B.⁠[5]

Requirement sets: R22, R23 and others

A requirement set links one or more test methods with limit values for each hazard level. The sets are designated by R and a number. For conformity, every test method in a set must be passed.⁠[3] The standard distinguishes between listed and non-listed components.⁠[6]

Which limits apply to R22 and R23?

R22 and R23 require a minimum oxygen index and maximum values for smoke density and toxicity index. R22 covers components inside the vehicle, R23 components outside. Assigned to them are, among others, seals, hoses, chokes and coils.⁠[6]

R22: maximum toxicity index CIT NLP per hazard levelHL1: R22: CIT NLP at most 1.2; HL2: R22: CIT NLP at most 0.9; HL3: R22: CIT NLP at most 0.75.HL1R22: CIT NLP at most 1.2HL2R22: CIT NLP at most 0.9HL3R22: CIT NLP at most 0.75
Maximum values of the toxicity index for R22 (interior components) according to published information. Table 5 of the standard is authoritative. Sources: [6], [9].
Limit values of requirement sets R22 and R23 according to published information
ParameterLevelR22 (interior)R23 (exterior)
Oxygen index in %, minimumHL1 / HL2 / HL328 / 28 / 3228 / 28 / 32
Smoke density Ds max at 25 kW/m², maximumHL1 / HL2 / HL3600 / 300 / 150– / 600 / 300
Toxicity index CIT NLP, maximumHL1 / HL2 / HL31.2 / 0.9 / 0.75– / 1.8 / 1.5
Sources: information sheet of a test laboratory [6] for the toxicity index; patent specification [9] for all parameters. Dash: no requirement. Table 5 of the standard is authoritative.

Whether a polyamide compound reaches the values for HL3 can only be shown by a test report.

Which other sets concern plastic parts?

For electrotechnical plastic parts the guide names R24 and R26. R24 applies to small quantities below certain mass limits and omits smoke density and toxicity. R26 applies to small electrotechnical products such as circuit breakers, contactors, terminals and fuses.⁠[4]

What applies to non-listed components?

For non-listed components up to 0.20 m² of exposed surface, smoke toxicity must be tested in the tube furnace, as for R22 and R23.⁠[6] Grouping rules also apply: components close to each other are assessed together, with mass and distance as the deciding factors.⁠[4]

Tests: the methods behind the values

Flat parts such as wall linings and seat shells are tested in the smoke chamber.⁠[7] The cone calorimeter to ISO 5660-1 determines heat release from oxygen consumption; the parameter evaluated is MARHE.⁠[3]⁠[12]

Test methods for plastics under EN 45545-2
TestStandard and editionParameterNote
Oxygen indexISO 4589-2:2017, confirmed 2022Oxygen index in percent by volumevertical specimen
Smoke densityISO 5659-2:2017, since 2026 ISO 5659:2026Ds max, Ds(4), VOF4specimen 75 mm × 75 mm
Smoke toxicity in the tube furnaceEN 17084:2018 + AC:2020, method 2CIT NLP1 g at 600 °C
Smoke toxicity in the smoke chamberEN 17084:2018 + AC:2020, method 1CIT Ggas analysis by FTIR
Heat releaseISO 5660-1:2015 with Amendment 1:2019MARHE in kW/m²cone calorimeter
Sources: abstracts [2], [10] to [12]; information sheets of a test laboratory [6] to [8]; test organisation [3].

How is the oxygen index determined?

The oxygen index is the lowest oxygen concentration in an oxygen–nitrogen mixture at which a small, vertically held specimen just continues to burn. Results are only comparable between specimens of the same form and thickness. If only a minimum value is to be demonstrated, a short procedure with ten specimens is sufficient.⁠[8]⁠[10]

How are smoke density and smoke toxicity measured?

Smoke density is measured optically in a closed chamber to ISO 5659-2, toxicity by gas analysis. The specimen is irradiated at 50 kW/m² without pilot flame or at 25 kW/m² with pilot flame; the measurement lasts ten minutes.⁠[7]

For R22 and R23, toxicity is determined in the tube furnace. There, 1 g of material is decomposed at 600 °C in a stream of air. Eight gases, including carbon monoxide, hydrogen chloride and hydrogen cyanide, give the dimensionless index CITNLP. The 2013 edition referred to the French standard NF X 70-100 for this; the current edition refers to EN 17084, method 2, which is based on this tube furnace test.⁠[2]⁠[6]

Editions, applications and limits

Which edition of EN 45545-2 applies?

The current edition is EN 45545-2:2020+A1:2023. The German edition DIN EN 45545-2:2023-12 replaces the edition of October 2020. Normative references and individual wording were changed, and Annex ZA was deleted.⁠[1] In its consolidated version of 27 April 2025, the TSI, Regulation (EU) No 1302/2014, names EN 45545-2:2020 as the specification for material requirements.⁠[5]

EN 45545 was published in 2013 and, after a three-year transition period, replaced the national standards in 2016.⁠[4] The TSI requires test reports to be renewed every five years. If the product is unchanged, a manufacturer's declaration is sufficient.⁠[5]

The texts of the standards are subject to a charge and were not available to the editors. The information comes from public abstracts, the freely available text of the regulation and documents from test laboratories. The text of the standard is authoritative.

Where are plastics used under EN 45545-2?

The evidence concerns plastic parts in and on the vehicle.

  • Electrical engineering: coil formers, terminals, contactors and circuit breakers.⁠[4]
  • Routing: hoses, seals and supply line systems inside and outside.⁠[6]
  • Interior: wall and ceiling linings and seat shells.⁠[7]

Where are the limits of the evidence?

A material is not approved for a hazard level in general.

  • Transferability: the oxygen index depends on specimen form and ignition conditions and does not describe the fire hazard in service.⁠[8]
  • Test standard: ISO 5659-2:2017 was replaced by ISO 5659:2026 in January 2026.⁠[11]
  • Installation: neighbouring components can change the classification through the grouping rules.⁠[4]

What the material supplier needs to know

The supplier needs this information:

  • Required hazard level: HL1, HL2 or HL3
  • Requirement set and installation location: interior (for example R22) or exterior (for example R23)
  • Required edition of EN 45545-2 and accepted age of test reports
  • Smallest and largest wall thickness of the part
  • Mass and exposed surface of the part, distance to neighbouring components
  • Mechanical and electrical requirements, colour, other approvals
  • Quantities and processing method

Frequently asked questions

What does EN 45545-2 govern?

EN 45545-2 governs the fire behaviour of materials and components in railway vehicles. It assigns components to requirement sets with limit values for each hazard level.

Which edition of EN 45545-2 is current?

The current edition is EN 45545-2:2020+A1:2023. The German edition is DIN EN 45545-2:2023-12.

What do HL1, HL2 and HL3 mean?

HL stands for hazard level. It follows from the operation category and design category of the vehicle. HL3 sets the highest requirements.

What is the difference between R22 and R23?

R22 applies to components inside the vehicle, R23 to components outside. R23 has less strict limits for smoke and toxicity.

Which oxygen index does R22 require for HL3?

According to published information at least 32 %, for HL1 and HL2 at least 28 %.

Does a polyamide meet HL3?

Not in general. Whether a polyamide compound reaches HL3 must be shown by a test report for exactly this grade, wall thickness and requirement set.

Is NF X 70-100 still valid?

For the toxicity test in the tube furnace, the current EN 45545-2 refers to EN 17084, method 2. This method is based on the tube furnace test to NF X 70-100.

How long is a test report under EN 45545-2 valid?

The TSI for locomotives and passenger rolling stock requires renewal every five years. If the product is unchanged, a declaration by the manufacturer is sufficient.

What applies to small parts not listed in the standard?

They are assessed by exposed surface and installation location. Grouping rules for neighbouring components also apply.

Sources

All sources retrieved and checked on 23 November 2026.

  1. DIN EN 45545-2:2023-12, Bahnanwendungen – Brandschutz in Schienenfahrzeugen – Teil 2: Anforderungen an das Brandverhalten von Materialien und Komponenten; German version EN 45545-2:2020+A1:2023. Title data and amendment note. https://www.dinmedia.de/de/norm/din-en-45545-2/372738387
  2. DIN EN 17084:2020-10, Bahnanwendungen – Brandschutz in Schienenfahrzeugen – Prüfung der Toxizität von Materialien und Komponenten; German version EN 17084:2018 + AC:2020. Title data and abstract. https://www.dinmedia.de/de/norm/din-en-17084/326164564
  3. TÜV NORD: Brandschutzprüfungen an Schienenfahrzeugen (fire tests on railway vehicles). Overview of operation and design categories, requirement sets and test methods. https://www.tuev-nord.de/de/dienstleistungen/pruefung-und-gutachten/brandschutzpruefungen-an-schienenfahrzeugen/
  4. ZVEI, German Electro and Digital Industry Association: Bahn EN 45545, Leitfaden zur Anwendung für Elektroisolierstoffe (guide to application for electrical insulating materials). Revision 2, November 2020. https://www.zvei.org/fileadmin/user_upload/Presse_und_Medien/Publikationen/2016/september/Bahn_EN_45545_Leitfaden_zur_Anwendung_fuer_Elektroisolierstoffe/Bahn_EN_45_545_Rev2._November_2020-11-24.pdf
  5. Regulation (EU) No 1302/2014 (TSI locomotives and passenger rolling stock), consolidated version of 27 April 2025. Point 4.2.10.2.1 and Appendix J-1, index 30. https://eur-lex.europa.eu/eli/reg/2014/1302/2025-04-27/eng/pdf
  6. CURRENTA Brandtechnologie (test laboratory accredited to DIN EN ISO/IEC 17025): information sheet on smoke toxicity to EN 45545-2, NF X 70-100 and EN 17084 method 2. As of 2024. https://www.currenta.de/wp-content/uploads/2024/08/EN_45545-2_20162023_Rauchgastoxiziaet_NF-X-70-100_2022.pdf
  7. CURRENTA Brandtechnologie: information sheet on smoke density and smoke toxicity to EN 45545-2, ISO 5659-2. https://www.currenta.de/wp-content/uploads/2026/01/EN_45545-2_20162023_Rauchdichte-Toxiziaet_ISO-5659-2.pdf
  8. CURRENTA Brandtechnologie: information sheet on oxygen index to EN 45545-2, ISO 4589-2. https://www.currenta.de/wp-content/uploads/2026/01/EN_45545-2_2023-Sauerstoff-Index-ISO-4589-2.pdf
  9. US Patent 11,686,410: Rubber composition for a cover layer of a hydraulic hose. Table with the requirements of sets R22 and R23. https://image-ppubs.uspto.gov/dirsearch-public/print/downloadPdf/11686410
  10. ISO 4589-2:2017, Plastics – Determination of burning behaviour by oxygen index – Part 2: Ambient-temperature test. 2nd edition, April 2017, confirmed 2022. Abstract. https://www.iso.org/standard/60786.html
  11. ISO 5659-2:2017, Plastics – Smoke generation – Part 2: Determination of optical density by a single-chamber test. 4th edition, May 2017; withdrawn in January 2026, replaced by ISO 5659:2026. Abstract. https://www.iso.org/standard/65243.html
  12. ISO 5660-1:2015, Reaction-to-fire tests – Heat release, smoke production and mass loss rate – Part 1. 3rd edition, March 2015, with Amendment 1:2019, confirmed 2026. Abstract. https://www.iso.org/standard/57957.html

Related topics