At a glance
- In Germany, the KTW assessment basis of the German Environment Agency applies, currently in the version of 5 October 2026.
- The formulation is checked against a positive list, plus migration at 23 °C and, depending on use, at 60 °C or 85 °C.
- Microbial growth is tested to DIN EN 16421:2015-05; method 2 is the volumetric method of the DVGW.
- From 31 December 2026, European positive lists, test methods and marking apply.
- For products with a valid national certificate, a transition period runs until 31 December 2032.
Germany: Drinking Water Ordinance and KTW assessment basis
Under section 14 of the German Drinking Water Ordinance, materials in contact with drinking water must not reduce health protection, must not impair colour, odour and taste and must not promote the growth of microorganisms. Under section 15, the German Environment Agency (Umweltbundesamt) sets assessment bases for this. They become binding two years after publication.[1]
What does the KTW assessment basis govern?
The assessment basis for plastics and other organic materials in contact with drinking water (KTW-BWGL) specifies which starting substances are permitted and how the finished material is tested. The current version is that of 5 October 2026 (seventh amendment). Annexes supplement the general part: A for plastics, B for organic coatings, C for lubricants, D for elastomers, E for thermoplastic elastomers. Silicones are not yet covered.[2]
What is assessed is not the material class, such as polyamide, but the individual formulation with all its starting substances.[2][4]
What role does the DVGW worksheet W 270 play?
The DVGW worksheet W 270 deals with the growth of microorganisms on materials. Its edition is November 2007.[6] DIN EN 16421:2015-05 contains three methods: biomass formation via ATP (method 1), the volumetric method of the DVGW (method 2) and oxygen depletion (method 3), which goes back to the British BS 6920.[5] For Germany, the KTW assessment basis only permits methods 1 and 2.[2] The German Environment Agency names method 2 and W 270 side by side.[4]
The standards and the worksheet are subject to a charge and were not available to the editors. The information comes from abstracts and official sources.
How is conformity confirmed?
The evidence is the certificate of a certifier accredited for this purpose. Under section 16 of the Drinking Water Ordinance, the requirements are then presumed to be met.[1] So far there is no obligation to certify, and no state approval is provided for.[4] The assessment basis assigns products to risk groups P1 to P4, which determine the scope of testing.[2]
Europe: Drinking Water Directive and the 2024 legal acts
On the basis of Article 11 of the Drinking Water Directive (EU) 2020/2184, six legal acts were published in the Official Journal on 23 April 2024. All of them apply from 31 December 2026.[3]
| Jurisdiction | Regulation and version | Evidence | Status and deadlines |
|---|---|---|---|
| Germany | Drinking Water Ordinance, sections 14 to 16; KTW-BWGL of 5 October 2026 | certificate of an accredited certifier | withdrawal announced for 31 Dec 2032 |
| European Union | Directive (EU) 2020/2184, Article 11; legal acts (EU) 2024/365 and 2024/367 to 2024/371 | EU certificate of a notified body, marking | applies from 31 Dec 2026, transition until 31 Dec 2032 |
| England and Wales | Water Supply (Water Fittings) Regulations 1999, Regulation 4 and Schedule 2 | for example WRAS material approval, testing to BS 6920 | approval expires after five years |
| USA | NSF/ANSI/CAN 61 | certification to the standard | edition not checked |
What changes on 31 December 2026?
From that day, products newly placed on the market need an EU certificate and the prescribed marking.[3] Implementing Decision (EU) 2024/367 contains the European positive lists, in Annex I the starting substances for organic materials. Every entry has an expiry date.[7] Implementing Decision (EU) 2024/368 sets the test methods.[8] Delegated Regulation (EU) 2024/370 governs conformity assessment: type examination for all risk groups, plus supervised quality assurance of production in groups 1 and 2 and internal production control in groups 3 and 4. Certificates of notified bodies are valid for five years.[9] Marking is governed by Regulation (EU) 2024/371.[3]
Which transition periods apply?
The transition period ends on 31 December 2032. For products with a national certificate valid on 31 December 2026, Regulation (EU) 2024/370 only applies from 31 December 2032.[9] Substances nationally approved between 13 July 2021 and 31 December 2026 may continue to be used until then.[7] The German Environment Agency will only update its assessment bases until 31 December 2026 and intends to withdraw them at the end of 2032.[3]
Other countries: United Kingdom, France, USA
Are WRAS, ACS or NSF valid in Germany?
No. According to the German Environment Agency, the test conditions and requirements for a WRAS or ACS certificate differ from the German ones.[4]
What does the United Kingdom require?
In England and Wales, Regulation 4 of the Water Supply (Water Fittings) Regulations 1999 requires every water fitting to conform to an appropriate British Standard or equivalent specification. Schedule 2 prohibits materials that can contaminate the water.[10] WRAS material approval demonstrates testing to BS 6920. Non-metallic materials are tested only for their effect on water quality. The approval expires five years after the date of the test report.[11]
What applies in the USA and in France?
The American standard NSF/ANSI/CAN 61 sets minimum requirements for substances that products and materials release into drinking water, for example pipes, fittings, valves and seals. It contains no requirements for odour, taste or microbial growth.[12] In France, under an order of 1997, organic materials need an Attestation de conformité sanitaire (ACS) from laboratories appointed by the state.[13]
Testing, components and limits
How does testing work?
Testing starts with the formulation. The manufacturer discloses all starting substances to the certification body, and they are checked against the positive list.[2][4] The test piece then stands in test water for ten days: at 23 °C for cold water, 60 °C for warm water, 85 °C for hot water.[2][8] In the migration water, odour, colour, turbidity, organic carbon and individual substances from the formulation are determined.[2]
| Test | Standard named in the decision | Criterion |
|---|---|---|
| Migration water | EN 12873-1:2014 | 23 °C always, 60 °C or 85 °C depending on use |
| Organic carbon (TOC) | EN 1484:1997 | at most 0.5 mg/l at the time of assessment |
| Odour and flavour | EN 1420:2016, EN 1622:2006 | threshold values per product type |
| Microbial growth | EN 16421:2015, method 1 or 2 | method 1: at most 1,000 pg ATP/cm² |
The European procedure goes further than the German one: cold water is also tested chlorinated, and unexpected substances are searched for by GC-MS, the coupling of gas chromatography and mass spectrometry.[2][3][8]
Which components does this apply to?
Covered are products that come into contact with drinking water in new construction or maintenance.[1][2]
- Domestic installation: pipes and their connectors. Pipes belong to the highest risk group.[2]
- Fittings and taps: plastic parts inside, cartridges and seals.[4]
- Household appliances: supply hoses.[4]
- Water supply: tanks and large pipes outside buildings.[2]
Where are the limits?
Evidence applies to a formulation, not to a material family.
- Intermediate material: a certificate for the granules only suffices up to risk group P2. In group P1, every component manufacturer needs its own confirmation.[4]
- Colour: masterbatches of the same colour can differ considerably, so every colour formulation is assessed.[4]
- Scope: filter media and ion exchangers are not covered by the European rules.[3]
What the material supplier needs to know
- Target markets: Germany, EU, United Kingdom, France, North America
- Evidence: KTW-BWGL or EU certificate
- Water temperature in service: cold, up to 60 °C or up to 85 °C
- Type of component and share of the wetted surface
- Pipe diameter or tank size
- Colour and colour variants
- Processing method at the component manufacturer
- Applicant for the certificate: material or component manufacturer
Frequently asked questions
What is the KTW-BWGL?
The KTW-BWGL is the German Environment Agency's assessment basis for plastics and other organic materials in contact with drinking water.
What is tested under DVGW W 270?
The test covers the growth of microorganisms on the material. The DVGW method is method 2 of DIN EN 16421:2015-05.
From when do the European rules for materials in drinking water contact apply?
The EU legal acts apply from 31 December 2026. For products with a valid national certificate, a transition period runs until 31 December 2032.
Is a polyamide approved for drinking water?
Not as a material class. What is assessed is the individual formulation with all its starting substances.
Is a WRAS approval also valid in Germany?
No. According to the German Environment Agency the requirements differ, and there is no general equivalence.
At which temperatures is testing carried out?
Cold water is tested at 23 °C, warm water at 60 °C and hot water at 85 °C.
Is a certificate for the granules sufficient?
Only up to risk group P2. In group P1, every component manufacturer needs its own confirmation.
What does NSF/ANSI/CAN 61 govern?
The standard sets minimum requirements for substances that products and materials release into drinking water.
Does the German Environment Agency approve products?
No. It sets the assessment bases; accredited certifiers confirm conformity.
Sources
All sources retrieved and checked on 23 November 2026.
- Trinkwasserverordnung (TrinkwV, German Drinking Water Ordinance) of 20 June 2023, sections 14 to 16. Full text, Federal Ministry of Justice. https://www.gesetze-im-internet.de/trinkwv_2023/__14.html
- Umweltbundesamt (German Environment Agency): Bewertungsgrundlage für Kunststoffe und andere organische Materialien im Kontakt mit Trinkwasser (KTW-BWGL), general part, version of 5 October 2026 (7th amendment). https://www.umweltbundesamt.de/system/files/document/KTW-BWGL_allgemeiner_Teil_-_7._%C3%84nderung.pdf
- Umweltbundesamt: information “Hygienische Anforderungen an Materialien und Werkstoffe im Kontakt mit Trinkwasser” (hygienic requirements for materials in contact with drinking water), transitional arrangements, Rev02 of 13 October 2025. https://www.umweltbundesamt.de/system/files/medien/5620/dokumente/uba-information_-_hygienische_anforderungen_an_materialien_und_werkstoffe_im_kontakt_mit_trinkwasser_uebergangsregelungen_-_rev02.pdf
- Umweltbundesamt: questions and answers on the assessment bases and confirmation of conformity, version 11 of 13 July 2026. https://www.umweltbundesamt.de/system/files/document/FAQ_Version_11_DE%20.pdf
- DIN EN 16421:2015-05, Influence of materials on water for human consumption – Enhancement of microbial growth. Abstract. https://www.dinmedia.de/en/standard/din-en-16421/208499971
- DVGW W 270:2007-11, Vermehrung von Mikroorganismen auf Werkstoffen für den Trinkwasserbereich – Prüfung und Bewertung (growth of microorganisms on materials for drinking water – testing and assessment). Entry in the standards directory. https://www.din.de/en/getting-involved/standards-committees/nal/publications/wdc-beuth:din21:104264545
- Commission Implementing Decision (EU) 2024/367 of 23 January 2024 (European positive lists). Official Journal L of 23.4.2024. https://eur-lex.europa.eu/eli/dec_impl/2024/367/oj?locale=de
- Commission Implementing Decision (EU) 2024/368 of 23 January 2024 (testing and acceptance of final materials). Official Journal L of 23.4.2024. https://eur-lex.europa.eu/eli/dec_impl/2024/368/oj
- Commission Delegated Regulation (EU) 2024/370 of 23 January 2024 (conformity assessment procedures). Official Journal L of 23.4.2024. https://eur-lex.europa.eu/eli/reg_del/2024/370/oj
- The Water Supply (Water Fittings) Regulations 1999, Regulation 4 and Schedule 2. Official UK legislation database. https://www.legislation.gov.uk/uksi/1999/1148/regulation/4
- Water Regulations Approval Scheme (WRAS): Material Approvals. Description of the procedure. https://www.wrasapprovals.co.uk/material-approvals/
- NSF: NSF/ANSI/CAN 61, Drinking Water System Components – Health Effects. Description of scope. https://www.nsf.org/knowledge-library/nsf-ansi-standard-61-drinking-water-system-components-health-effects
- Arrêté du 29 mai 1997 relatif aux matériaux et objets utilisés dans les installations fixes de production, de traitement et de distribution d'eau destinée à la consommation humaine (France), Légifrance; with the French Ministry of Health's overview of the ACS. https://www.legifrance.gouv.fr/jorf/id/JORFTEXT000000749834
Related topics
- Food contact
Regulation (EU) No 10/2011, migration and the declaration of compliance for plastics in contact with food. - Medical and hygiene
Biocompatibility, sterilisation and change control for plastics in medical devices. - Colour
Colour matching, colour systems, colour difference and laser marking. - Soft and tough to hard and stiff
Shore hardness, modulus, impact modification and thermoplastic elastomers.
This page is technical information, not advice on standards, law or design. The standards cited in their current edition and the material manufacturers' test reports are authoritative.